// hbapiwmi.h
void GetPersistentBinding2(
[in, HBAType("HBA_WWN")] uint8 PortWWN[8],
[in] uint32 InEntryCount,
[out, HBA_STATUS_QUALIFIERS] HBA_STATUS HBAStatus,
[out] uint32 TotalEntryCount,
[out] uint32 OutEntryCount,
[out, WmiSizeIs("OutEntryCount")] HBAFCPBindingEntry2 Bindings[]
);
View the official Windows hardware development documentationNo description available.
The GetPersistentBinding2 method retrieves the bindings that an HBA miniport driver uses to map the information that an operating system uses to identify its logical units to the Fibre Channel protocol (FCP) identifiers for the logical units.
PortWWN[8] A worldwide name that indicates the port whose persistent bindings will be retrieved.
InEntryCount Indicates the number of binding entries that the WMI provider can report in the Entry parameter.
HBAStatus On return, contains the status of the operation. For a list of allowed values and their descriptions, see HBA_STATUS. The miniport driver returns this information in the HBAStatus member of a GetFcpPersistentBinding_OUT structure.
TotalEntryCount Indicates the total number of persistent bindings associated with the HBA.
OutEntryCount Indicates the total number of persistent bindings retrieved by the GetPersistentBinding2 method.. This value will be less than or equal to TotalEntryCount.
Bindings[] An array of structures of type HBAFCPBindingEntry2 that describe an HBA's bindings between operating system and Fibre Channel protocol (FCP) identifiers.
Not applicable to WMI methods.
This WMI method belongs to the MSFC_HBAFCPInfo WMI Class.
| Target platform | Desktop |
| Header | Hbapiwmi.h (include Hbapiwmi.h, Hbaapi.h, or Hbaapi.h) |